The sterilizer panel, finally connected

The can retort or the tomato paste evaporator is the critical machine of a canning plant, and it usually has a proprietary panel with no network. With iLEAN Connect an external camera reads the screen, builds the temperature, pressure and time curve of each cycle and links it to the lot, without touching the PLC or the control logic.

‹ See all cases of sauces and canned vegetables

Camera on an external bracket aimed at a horizontal sterilizer screen showing a temperature curve, crates of cans beside it and a technician in a hairnet reading the lot curve on a tablet
The problem

The machine that makes the can safe keeps its memory on a paper chart.

Thermal process equipment lasts for decades. Replacing its control is expensive and requires revalidating the process, so it keeps running with isolated panels and paper chart recorders. As a result, the most important data for the safety and quality of a canned product, its thermal history, lives on paper or on a refreshing screen. When a complaint arrives or a lot is held, matching that lot with its real cycle takes hours.

  • The can sterilizer and the paste evaporator outlast several ERPs. Replacing their control means revalidating the thermal process, so they keep running with proprietary panels and no network.
  • Their thermal history, the single most important record for a canned product's safety, lives on a chart recorder roll or on a screen that refreshes every few seconds.
  • In season the equipment runs day and night, and the chart rolls pile up in a cabinet, labeled by date, not by lot.
  • When a complaint arrives or a lot is held, matching it to its real cycle means unrolling paper for hours, often with the customer waiting for an answer.
How it fits the IRIS system

Connect in panel photo mode — the camera reads what the process lead reads.

iLEAN Connect in panel photo mode.

Nothing is wired into the PLC and nothing in the control logic changes, so the validated process stays validated. What the plant gains is every cycle as a digital curve, tied to the lot the ERP says was inside, and signed off by the thermal process lead on a tablet. The chart roll stops being the only witness of the most important minutes in the life of a can. And when a lot is held, quality answers with its curve instead of a roll of paper.

  • Fixed industrial camera on an external bracket in front of the panel.
  • Screen reading every few seconds with OCR and a grounded model.
  • Curve reconstruction per cycle and alarm detection.
  • ERP match to know which lot was in the equipment.
  • Review and sign-off by the thermal process lead on a tablet. No wires to the PLC: external, decoupled capture.

See the full IRIS architecture →

Before and after

The chart recorder roll versus the curve read from the panel

AspectTodayWith iLEAN Connect
Where the thermal history livesA paper roll in a cabinetA digital curve per cycle
Filed byDate and shiftLot and production order
Alarms during the cycleSeen if someone was thereLogged with their time
Paste evaporator readingsGlanced at, not keptStored as a time series
Sign-off by the process leadInitials on the rollDigital, on the tablet
Control retrofitOn the capex listPostponed

Before: paper curves, manual cycle-to-lot correlation, no digital history. After: thermal curve per lot available in seconds, alarms logged, digital sign-off by the process lead.

Impact estimate

Impact estimate — to be validated with your sterilizer and evaporator hours.

The block below is an estimate to be validated against your plant's actual data. We put it forward so the committee has an order of magnitude; we refine it during the assessment.

  • Estimated payback 5-10 months.
  • On top of that, a costly control retrofit can be postponed, because a digital record no longer depends on replacing the panel.
  • Cycle-to-lot correlation goes from a manual search through paper to a curve available in seconds.
  • And every alarm during the season is logged with its time and lot, ready for the process lead's digital sign-off. Answering a complaint about a lot becomes a matter of opening its curve.

Estimated payback of 5 to 10 months, plus postponing a costly control retrofit. Estimate to be validated.

And the fair question from the production manager

"A camera filming a screen as our thermal record?" — the reading is anchored: the same screen, the same field positions and a physically bounded range of temperature and pressure, where the best models stay under 1.5% error [1]. Any frame whose value falls outside what the sterilizer can physically reach is discarded and flagged, never stored. And the thermal process lead reviews and signs every cycle on the tablet, so the curve carries a name before it becomes evidence.

[1] OpenAI paper "Why Language Models Hallucinate", 2025 — on the reliability of AI in anchored tasks.

Frequently asked questions

What people ask about reading the sterilizer and evaporator panels

Does the PLC or the validated thermal process have to be touched?

No. The camera sits on an external bracket in front of the panel and no cable goes into the controller. The control logic and its validation stay exactly as they are.

How often is the screen read?

Every few seconds, which is enough to rebuild the full temperature, pressure and time curve of a cycle. Alarms that flash briefly on the panel are captured as well, with their time. A frame the model cannot read cleanly, because of glare or a passing operator, is skipped and the gap is marked, never filled in.

Does it work on a continuous sterilizer, not just batch cycles?

Yes. On continuous equipment the curve is cut by lot using the ERP's record of which lot was entering and leaving at each minute. Each lot ends up with its own slice of the thermal history. A lot that straddles a stop and a restart keeps both parts of its curve, with the stop visible between them.

Can the paste evaporator be read with the same setup?

Yes, the pattern is identical: a camera, a fixed screen and a model that knows where each value sits. Many plants start with the sterilizer and add the evaporator in the same season. The evaporator's history then explains why one batch of paste reached its Brix slower than another.

Should we keep the chart recorder during the first weeks?

That is our advice. Running both lets quality compare the digital curve against the paper roll until it trusts it; the roll can then be retired when your procedures allow it. The decision stays with quality and with whoever holds authority over the thermal process.

Let's talk

Send us a photo of your sterilizer panel and we will tell you what we can read.

We work on your plant's real data, not ours. Assessment with no commitment.

Request estimated ROI within 48h ‹ See all cases of sauces and canned vegetables See food industry