The hour-by-hour board stops being erased: losses by line and model in minutes

In a plant building clusters and displays, every line has an hour-by-hour board. The supervisor writes down by hand how many units came out against plan and why the hour was lost: missing material, model changeover, tester failure, AOI tuning. It is the most honest data in the plant, and it is wiped at the end of the shift. With iLEAN Connect, the supervisor takes a photo of the board every hour or at shift end, and another of the line start-up sheet. iLEAN reads plan, actual, gap and reason, and stores them structured by line, model and shift. Nobody changes habits: people keep writing on the board.

‹ See all cases of cockpit electronics

Supervisor photographing a handwritten hourly losses board with plan, actual and reasons such as AOI failures and feeder jam, next to an SMT line and a tablet showing losses by cause
The problem

The most honest data on a cluster line is wiped with an eraser.

In a plant building clusters and displays, every line has an hour-by-hour board. The supervisor writes down by hand how many units came out against plan and why the hour was lost: missing material, model changeover, tester failure, AOI tuning. It is the most honest data in the plant, and it is wiped at the end of the shift. What reaches the system is the final unit count, not the cause. Operational excellence needs the real loss Pareto by line and by model, but the root cause lives in marker ink. Shift start-up meetings run on memory.

  • Every SMT and final assembly line has its hour-by-hour board: plan, actual and the reason the hour was lost — missing reel, model changeover, tester failure, AOI tuning. It is written in real time by the person who saw it happen.
  • At shift end the board is wiped. The MES keeps the final unit count per model, but not why the gap opened at 10:00 on line 3 or which variant was running when it did.
  • Operational excellence asks for the real loss Pareto by line and by model, and gets an estimate built from whoever remembers the night shift best. Two people asked about the same week usually give two different top causes.
  • So the shift start-up meeting runs on memory, and Kaizen effort goes to the loudest cause instead of the one that actually cost the most cluster and display units over the month.
How it fits the IRIS system

Connect in photo mode — the supervisor keeps writing on the hour-by-hour board.

With iLEAN Connect, the supervisor takes a photo of the board every hour or at shift end, and another of the line start-up sheet. iLEAN reads plan, actual, gap and reason, and stores them structured by line, model and shift. Nobody changes habits: people keep writing on the board. Before anything enters the system, the supervisor sees on the tablet what iLEAN has read and confirms it with two taps. Humans in command: the AI reads, the person validates. It fits the IRIS architecture as the Connect piece of the iLEAN system.

Nobody asks the line to change habits: the marker stays, the board stays, and one photo per hour turns it into data. On lines that change model several times per shift, that is the only practical way to see which variant, which feeder bank or which tester actually eats the hours.

See the full IRIS architecture →

Before and after

The erased board versus the board read by iLEAN

AspectTodayWith iLEAN Connect
Loss reason per hourWiped at shift endStored by line, model and shift
Changeover hoursMixed with every other stoppageSeparated per variant and line
Feeder and AOI tuning lossesRemembered, roughlyCounted hour by hour
Start-up meetingRun on memoryRun on yesterday's Pareto
Supervisor effortWrite, then retype for the reportWrite, then one photo
Kaizen targetThe loudest causeThe cause that cost most units

Before: loss reasons that disappear with the eraser. After: a loss Pareto by line, model and shift available within minutes, and start-up meetings run on data, not memories.

Impact estimate

Impact estimate — to be validated with your numbers.

The block below is an estimate to be validated against your plant's actual data. We put it forward so the committee has an order of magnitude; we refine it during the assessment.

  • Estimated payback 3-8 months, depending on the number of SMT and final assembly lines photographed.
  • +1-3 OEE points expected from focusing Kaizen on the real loss Pareto instead of the perceived one, which is where improvement teams usually lose months.
  • Changeover hours separated from material and tester stoppages, which is what tells you whether to attack SMED or supply first.
  • And the start-up meeting moves from opinions about the night shift to yesterday's numbers by line and model, in the same fifteen minutes it takes today. An estimate to be validated with your data.

Payback 3-8 months · +1-3 OEE points from the real loss Pareto. Focusing Kaizen on the real causes typically recovers one to three OEE points. Estimated payback of three to eight months depending on the number of lines. An estimate to be validated with your data.

And the fair question from the production manager

“Can it really read a supervisor's handwriting on a whiteboard photographed at an angle?” — the board has a known grid: hour, plan, actual, reason. Reading fields from a fixed structure is an anchored task, where the best models drop below 1.5% error [1]. And there is a second net: the supervisor sees on the tablet what iLEAN read and confirms it with two taps before anything is stored, so a smudged digit never reaches the Pareto unchecked.

[1] OpenAI paper "Why Language Models Hallucinate", 2025 — on the reliability of AI in anchored tasks.

Frequently asked questions

What people ask about photographing the hour-by-hour board on SMT lines

Do we need a new board layout for cluster and display lines?

No. iLEAN learns the columns your boards already have, including handwritten abbreviations for feeder, AOI or tester. If one line uses a different layout, that line simply gets its own template at start-up. The supervisor keeps the marker and the habit.

How does it know which model was running in a given hour?

From the start-up sheet photo and the model written on the board, crossed with the MES sequence when it is connected. A changeover in mid-hour is split between both variants, so neither model carries the other's loss.

What if the reason column says only 'material'?

It is stored as written and flagged as an unspecific reason. After a few weeks the Pareto itself shows how much of the loss hides behind vague words, and tightening those words is usually the first improvement.

Is one photo at shift end enough, or every hour?

Both work. One photo at shift end already gives the Pareto; hourly photos give the timing, which is what you need to see whether losses cluster after changeovers, breaks or the first hour of the night shift. Most plants start with shift end and move to hourly once they see the first Pareto.

Does this replace OEE data from the SMT machines?

No, it complements it. Placement machines log their own stops; the board explains the hours lost outside them, such as waiting for a reel, a free tester or a first-article release that nobody signed yet.

Let's talk

Tell us how many lines you run and what your hour-by-hour boards look like today.

We work on your plant's real data, not ours. Assessment with no commitment.

Request estimated ROI within 48h ‹ See all cases of cockpit electronics See automotive