Inline vision: pins and terminals at one hundred percent

On a connector assembly line, a bent pin or unseated terminal can stop the customer's line. iLEAN Edge inspects one hundred percent of parts with a camera and a model trained on your part numbers, rejects the defective one before packing and explains the defect to the cell lead.

‹ See all cases of electronic connectors

Ring-lit industrial camera above a conveyor of multi-pin connectors, with a pneumatic pusher diverting a defective part into a reject bin while a technician reads defect statistics on a tablet
The problem

The defect that stops a customer's line is smaller than a millimeter.

A connector assembly line produces thousands of parts per hour. The defect that matters is small: a bent pin, an unseated terminal, a short shot in the housing, flash on the contact area. At that rate, human visual inspection tires and sampling leaves gaps. A single bent pin reaching an automotive customer's line can stop their production and open a formal complaint.

  • A connector line turns out thousands of parts per hour. The defects that matter are tiny: a bent pin, a terminal not fully seated in its cavity, a short shot in the housing, flash on the contact area. Most of them are invisible at arm's length, and some only show from a specific angle.
  • At that rate a human eye tires, and sampling leaves gaps between samples by design, exactly where a single bad connector hides.
  • A single bent pin reaching an automotive customer can stop their production and open a formal complaint with a PPM penalty and a sorting bill.
  • When the escape is found, tracing it back to the mold cavity, the insertion station or the strip lot is slow, because sampling left no record of the parts in between, and the containment has to be wide. Every unchecked part between two samples is suspect.
How it fits the IRIS system

Edge — local inference on every part, before the connector is packed.

iLEAN Edge places an industrial camera over the line's critical point and a vision model trained on good and bad parts of your part numbers. It infers in milliseconds, locally, without sending images to the cloud. The defective part is rejected before packing and the cell lead sees on the tablet which defect it was, which cavity or station, and how often. They decide whether to stop the line or adjust.

Inspecting one hundred percent is only half the gain. The other half is knowing which cavity or insertion station produces the defect, which turns a reject bin into a maintenance order. The cell lead decides whether to stop or adjust. A cavity that starts producing short shots shows up in the statistics within the hour, not in next month's complaint.

See the full IRIS architecture →

Before and after

Sample checks versus Edge on every connector

AspectSample inspectionWith iLEAN Edge
Share of connectors inspectedA sample per lotEvery one
Terminal not fully seatedMissed between samplesCaught and rejected
Short shot or flash on the housingDepends on the inspector's hourClassified at line speed
Defects by mold cavityUnknownCounted per cavity
Images leaving the plant—None: inference is local
Decision to stop the lineTaken on suspicionTaken on statistics

Before: sample inspection, occasional escapes to the customer, root cause hard to trace. After: 100% inspection, immediate rejection, statistics per cavity and station.

Impact estimate

Impact estimate — to be validated with your numbers.

The block below is an estimate to be validated against your plant's actual data. We put it forward so the committee has an order of magnitude; we refine it during the assessment.

  • Estimated payback 5-12 months, depending on your current reject level and the cost of each complaint you receive today.
  • Customer escapes reduced by 30% or more in the families covered, as an estimate to validate on your own lines.
  • Statistics per cavity and per insertion station that point maintenance at the real source of the defect, whether that is a worn cavity or an insertion head out of adjustment.
  • Fewer PPM points lost on the customer scorecard, and fewer formal complaints to answer, each with its 8D and its sorting cost.

Estimated payback of 5 to 12 months depending on current reject level and the cost of each complaint; customer escapes reduced by 30% or more. Estimate to be validated.

And the fair question from the production manager

“What if it rejects good connectors?” — false rejects are the real risk of any vision system, so the model is trained on good and bad parts of your own part numbers under that station's lighting. Classifying known defect types on a fixed presentation is an anchored task, where the best models stay below 1.5% error [1], and borderline cases go to the cell lead instead of straight to scrap. Each of those decisions feeds back into training, so the model gets sharper on exactly the cases that are hard for your part numbers.

[1] OpenAI paper "Why Language Models Hallucinate", 2025 — on the reliability of AI in anchored tasks.

Frequently asked questions

What people ask about inline vision for pins and terminals

Can it see a terminal that is seated but not locked?

When the lock position is visible from the camera angle, yes; that is defined per part number during commissioning, together with any second camera needed. Some locks need a side view, and that is decided by looking at real parts, not on paper.

How many defective connectors are needed for training?

Fewer than expected, because connector defects form a short, repetitive catalog. What matters is that they are real parts from your own part numbers, imaged under the station's lighting. A few dozen examples per defect type is a typical starting point.

Does it keep up with high-speed connector lines?

Yes. Inference runs locally on the edge device in milliseconds per part, independent of the plant network and the cloud. No images leave the plant, which matters when the connector design belongs to the customer.

Does it replace the electrical tester?

No. The tester checks continuity; the camera checks geometry. A bent pin can pass continuity and still fail at the customer's mating connector. The two checks complement each other, and the tester keeps its role as the electrical reference.

What happens with a new connector part number?

A model is trained for it with a short set of real samples, and the camera switches model according to the active work order. Nobody selects it by hand, so a part number change cannot leave the wrong model running.

Let's talk

Tell us how many of last year's complaints started with a bent pin or an unseated terminal.

We work on your plant's real data, not ours. Assessment with no commitment.

Request estimated ROI within 48h ‹ See all cases of electronic connectors See electronics