iLEAN Connect · PLC connectors
Connect a fruit pulper to AI — plug & play iLEAN Connect connector
On a pulper the margin escapes out the waste chute. Connecting it means measuring how much pulp is leaving with what you throw away.
The reference signal is a split: kilos of fruit fed against kilos of pulp obtained, with waste as the difference. Beside it sit the signals that explain why the split moves — paddle motor load, which climbs as the screen blinds; working speed; level or pressure in the feed hopper; jam stoppages, and cleaning and screen-change times.
On the panel the manager sees pulp yield per delivery and its drift within the shift. The curve is recognisable: the machine starts strong, the screen loads up and yield falls slowly until someone decides to stop and clean. Connected, that decision stops being habit: the iLEAN agent flags when the accumulated loss already costs more than the cleaning stop.
The typical connection combines what the machine offers — an embedded controller if it is recent, or simply its cabinet — with whatever weighing or flow already exists upstream and downstream. If a measuring point is missing to close the balance, it is proposed in the scope document and included in the same quote.
The final decision is about recovery: match screen and speed to the fruit in this delivery, and know whether the waste leaving the side chute still carries pulp worth recovering on a second pass.
Your machine connects, whether or not you know what is inside it
If it has no PLC
Plenty of machines in production predate the network. They connect all the same: an industrial camera watches the panel and reads what it shows, or the paper logs filled in by hand are captured by photo. Without touching the machine and without affecting its warranty.
If the PLC is embedded and you don't know which one
That is the norm. The builder fitted it under the housing and the documentation never says. You do not need to know: we identify it during the technical visit and the scope follows from there. You do not have to research anything before writing to us.
If you do know the PLC
Even better: there is probably already a standard connector for that family. Check the PLC connector catalog.
How it works
- Define the scope. Tell us what you want to see from your machine in the form. The form itself is the scope document: no separate paperwork.
- Quoted in 24 hours. You receive the quote within 24 business hours. If your connector is standard, direct activation — from €79/month per machine.
- Running in under 7 days. From your approval of the quote, the integration is running in under 7 days. You pay once you confirm it does what you expected.
What you get with the connector
- A panel of your machine, always visible, with history and charts.
- The iLEAN central memory continuously fed with signals, states, counters, alarms and variables.
- An AI agent analyzing the data and flagging deviations.
- A daily email summary of what happened on your line.
- Optional push to your ERP.
The connector is the doorway to the rest of the system: when you need it, the same machine scales to iLEAN Edge (inline machine vision, millisecond loop) and iLEAN Agents (full-cycle agents on the central memory).
How the guarantee works
Every iLEAN Connect integration is contracted the same way, and the terms are right here in the open:
- You define the scope of the connection you want: which signals, states, counters, alarms and variables to read from your PLC or machine.
- iLEAN quotes it within 24 business hours.
- If you approve, iLEAN builds it in under 7 days. The clock starts at your approval of the quote.
- iLEAN presents the integration to you, running.
- You confirm it does what you expected — the criterion is written into the scope document itself.
- Only then do you pay. Integrations 100% at reversed risk.
Need the AI to also act on the line? Define it in the scope and we quote it in 24 hours all the same; the build time is agreed in the scope document.
This guarantee covers the standard data connector: reading signals, states, counters, alarms and variables, delivery to the iLEAN central memory, a panel with history and charts, an agent analyzing, a daily email summary and optional push to your ERP.
The price, in the open
Standard catalog connector
From €79/month per machine. Your machine always online in the central memory, a panel with history, an agent analyzing and a daily email summary.
Custom integration
Its price is the 24-hour quote. The build is quoted once; afterwards, your machine joins the same fee — from €79/month.
Several machines with the same PLC? Volume pricing is negotiated case by case — ten identical connectors do not cost ten fees.
Why iLEAN can promise this
25+ years integrating AI with plant automation. Every driver, every protocol, every quirk of every PLC family is solved because it was already solved in a real plant: at Tier-1 manufacturers across automotive, aerospace, food, pharma and chemicals, and at the industrial SMEs that supply them.
AI is one more sensor — one that sees. Your PLC receives iLEAN's signal the way it receives any sensor's.
Frequently asked questions
Do we have to touch the PLC program?
No. The connector reads non-intrusively: AI is one more sensor, and your control logic stays exactly as it is. Writing to the PLC only exists if you expressly request it in the scope document.
What if the integration doesn't do what we expected?
You don't pay for it. The scope document defines in writing what «does what you expected» means, and payment comes after you confirm it, watching the integration run.
What network requirements does it need?
An outbound path from the plant network to the iLEAN central memory, with no inbound access opened. The concrete architecture — zones, rings, who talks to whom — is detailed in the scope document.
What if my machine has no PLC?
It connects too: through a camera on the panel or a photo of the paper log, the same iLEAN Connect paths used by plants with pre-network machinery.
Can yield be estimated without weighing the waste?
Yes, by closing the balance with what is already measured: fruit fed and pulp obtained. Waste comes out as the difference. If you also want the direct figure, the weighing point is added in the scope and priced with everything else.
Is motor load useful for deciding when to change the screen?
It is the most useful of the indirect signals: the load trend at equal product and speed describes screen blinding. With a few weeks of history the agent learns your machine's normal pattern and flags it before yield suffers.
More cases in connect any machine to ai
- Connect a fruit grader to AI — plug & play iLEAN Connect connectorSize and outlet distribution in real time, so you know what you can commit to your customer today.…
- Connect a fruit pitter to AI — plug & play iLEAN Connect connectorStrokes per minute against fruit actually pitted, feed gaps and rework. Quoted in 24h, running in under…
- Connect an industrial fruit press to AI — plug & play iLEAN Connect connectorPressing yield per delivery, cycles and applied pressure, and when the cloth is spent. Quoted in 24h,…
- Connect a fruit waxer to AI — plug & play iLEAN Connect connectorWax applied per tonne, uniformity across the shift and packhouse line stoppages. Quoted in 24h, running…
- Connect an industrial blancher to AI — plug & play iLEAN Connect connectorReal blanching time and bath temperature, batch by batch, recorded. Quoted in 24h, running in under 7…
- Connect an industrial peeler to AI — plug & play iLEAN Connect connectorKilos in, kilos out and which batch sent peeling waste through the roof. Quoted in 24h, running in under…
This form is the scope document: from what you write here, iLEAN prepares your quote. You have it within 24 business hours.
SIMATIC, S7 and LOGO! are trademarks of Siemens AG. Allen-Bradley, ControlLogix, CompactLogix, MicroLogix, Micro800 and SLC are trademarks of Rockwell Automation, Inc. Modicon is a trademark of Schneider Electric. MELSEC is a trademark of Mitsubishi Electric Corporation. SYSMAC is a trademark of OMRON Corporation. TwinCAT and EtherCAT are trademarks of Beckhoff Automation GmbH & Co. KG. X20 is a trademark of B&R Industrial Automation. AC500 is a trademark of ABB. PLCnext is a trademark of Phoenix Contact GmbH & Co. KG. WAGO and PFC are trademarks of WAGO GmbH & Co. KG. PACSystems and VersaMax are trademarks of Emerson Electric Co. PROFINET and PROFIBUS are trademarks of PROFIBUS Nutzerorganisation e.V. EtherNet/IP and CIP are trademarks of ODVA, Inc. OPC UA is a trademark of the OPC Foundation. Modbus is a trademark of Schneider Electric, licensed to the Modbus Organization. All other marks belong to their respective owners. iLEAN is not affiliated with, sponsored by, or endorsed by any of these manufacturers; their marks are used solely to identify the equipment and protocols iLEAN Connect connectors are compatible with.