iLEAN Connect · PLC connectors
Connect a fruit pitter to AI — plug & play iLEAN Connect connector
A pitter can run flat out while feeding on empty cups. The number that matters is how much fruit came out properly pitted per stroke the machine made.
A pitter's headline signal is misleading: strokes per minute measure what the machine does, not what the product does. Connecting it puts the signals that do count alongside — fruit actually processed, feed gaps, the size grade being run, the current punch setting, jam stoppages and, where there is outfeed control, rework from stones left in or damaged flesh.
On the panel that becomes one useful reading: cycle utilisation per fruit delivery. It shows the moment an irregular-grade delivery starts, because gaps climb before anyone notices anything on the belt. The iLEAN agent flags that drift — precisely the moment when stopping two minutes to readjust still pays off, instead of finishing the delivery at half efficiency.
Many seasonal pitters are mechanical, with nothing to read beyond their own start signal; there, cycles are counted with our own sensors and the panel is read by camera. Recent inline units carry an embedded controller. Either way, what gets connected and how is written into the scope document after the technical visit.
The decision is a campaign decision: readjust by size grade at the right moment, separate the deliveries that do not perform before they get mixed in, and know at close of season which fruit supplier was genuinely cheap once rework is deducted.
Your machine connects, whether or not you know what is inside it
If it has no PLC
Plenty of machines in production predate the network. They connect all the same: an industrial camera watches the panel and reads what it shows, or the paper logs filled in by hand are captured by photo. Without touching the machine and without affecting its warranty.
If the PLC is embedded and you don't know which one
That is the norm. The builder fitted it under the housing and the documentation never says. You do not need to know: we identify it during the technical visit and the scope follows from there. You do not have to research anything before writing to us.
If you do know the PLC
Even better: there is probably already a standard connector for that family. Check the PLC connector catalog.
How it works
- Define the scope. Tell us what you want to see from your machine in the form. The form itself is the scope document: no separate paperwork.
- Quoted in 24 hours. You receive the quote within 24 business hours. If your connector is standard, direct activation — from €79/month per machine.
- Running in under 7 days. From your approval of the quote, the integration is running in under 7 days. You pay once you confirm it does what you expected.
What you get with the connector
- A panel of your machine, always visible, with history and charts.
- The iLEAN central memory continuously fed with signals, states, counters, alarms and variables.
- An AI agent analyzing the data and flagging deviations.
- A daily email summary of what happened on your line.
- Optional push to your ERP.
The connector is the doorway to the rest of the system: when you need it, the same machine scales to iLEAN Edge (inline machine vision, millisecond loop) and iLEAN Agents (full-cycle agents on the central memory).
How the guarantee works
Every iLEAN Connect integration is contracted the same way, and the terms are right here in the open:
- You define the scope of the connection you want: which signals, states, counters, alarms and variables to read from your PLC or machine.
- iLEAN quotes it within 24 business hours.
- If you approve, iLEAN builds it in under 7 days. The clock starts at your approval of the quote.
- iLEAN presents the integration to you, running.
- You confirm it does what you expected — the criterion is written into the scope document itself.
- Only then do you pay. Integrations 100% at reversed risk.
Need the AI to also act on the line? Define it in the scope and we quote it in 24 hours all the same; the build time is agreed in the scope document.
This guarantee covers the standard data connector: reading signals, states, counters, alarms and variables, delivery to the iLEAN central memory, a panel with history and charts, an agent analyzing, a daily email summary and optional push to your ERP.
The price, in the open
Standard catalog connector
From €79/month per machine. Your machine always online in the central memory, a panel with history, an agent analyzing and a daily email summary.
Custom integration
Its price is the 24-hour quote. The build is quoted once; afterwards, your machine joins the same fee — from €79/month.
Several machines with the same PLC? Volume pricing is negotiated case by case — ten identical connectors do not cost ten fees.
Why iLEAN can promise this
25+ years integrating AI with plant automation. Every driver, every protocol, every quirk of every PLC family is solved because it was already solved in a real plant: at Tier-1 manufacturers across automotive, aerospace, food, pharma and chemicals, and at the industrial SMEs that supply them.
AI is one more sensor — one that sees. Your PLC receives iLEAN's signal the way it receives any sensor's.
Frequently asked questions
Do we have to touch the PLC program?
No. The connector reads non-intrusively: AI is one more sensor, and your control logic stays exactly as it is. Writing to the PLC only exists if you expressly request it in the scope document.
What if the integration doesn't do what we expected?
You don't pay for it. The scope document defines in writing what «does what you expected» means, and payment comes after you confirm it, watching the integration run.
What network requirements does it need?
An outbound path from the plant network to the iLEAN central memory, with no inbound access opened. The concrete architecture — zones, rings, who talks to whom — is detailed in the scope document.
What if my machine has no PLC?
It connects too: through a camera on the panel or a photo of the paper log, the same iLEAN Connect paths used by plants with pre-network machinery.
How is incoming fruit counted when it arrives in bulk?
With what the plant already uses: the tipper or bin weight, the count from the grader upstream, or the machine's own cycles corrected by a size-grade factor agreed in the scope. How much precision each plant needs is decided before quoting, not after.
Can line rejects be traced back to what the pitter was doing?
Yes, when both points are connected and share batch and timestamp. It is the most common use: cross downstream rejects against the setting and the size grade running on the pitter at that moment.
More cases in connect any machine to ai
- Connect an industrial citrus juicer to AI — plug & play iLEAN Connect connectorLitres of juice per fruit delivery, jam stoppages and yield drift through the day. Quoted in 24h, paid…
- Connect a fruit dehydrator to AI — plug & play iLEAN Connect connectorThe drying curve each load actually received and the energy spent per batch. Quoted in 24h, running in…
- Connect a fruit grader to AI — plug & play iLEAN Connect connectorSize and outlet distribution in real time, so you know what you can commit to your customer today.…
- Connect an industrial fruit press to AI — plug & play iLEAN Connect connectorPressing yield per delivery, cycles and applied pressure, and when the cloth is spent. Quoted in 24h,…
- Connect a fruit pulper to AI — plug & play iLEAN Connect connectorPulp obtained against waste ejected, and when the screen starts costing you money. Quoted in 24h, paid…
- Connect a fruit waxer to AI — plug & play iLEAN Connect connectorWax applied per tonne, uniformity across the shift and packhouse line stoppages. Quoted in 24h, running…
This form is the scope document: from what you write here, iLEAN prepares your quote. You have it within 24 business hours.
SIMATIC, S7 and LOGO! are trademarks of Siemens AG. Allen-Bradley, ControlLogix, CompactLogix, MicroLogix, Micro800 and SLC are trademarks of Rockwell Automation, Inc. Modicon is a trademark of Schneider Electric. MELSEC is a trademark of Mitsubishi Electric Corporation. SYSMAC is a trademark of OMRON Corporation. TwinCAT and EtherCAT are trademarks of Beckhoff Automation GmbH & Co. KG. X20 is a trademark of B&R Industrial Automation. AC500 is a trademark of ABB. PLCnext is a trademark of Phoenix Contact GmbH & Co. KG. WAGO and PFC are trademarks of WAGO GmbH & Co. KG. PACSystems and VersaMax are trademarks of Emerson Electric Co. PROFINET and PROFIBUS are trademarks of PROFIBUS Nutzerorganisation e.V. EtherNet/IP and CIP are trademarks of ODVA, Inc. OPC UA is a trademark of the OPC Foundation. Modbus is a trademark of Schneider Electric, licensed to the Modbus Organization. All other marks belong to their respective owners. iLEAN is not affiliated with, sponsored by, or endorsed by any of these manufacturers; their marks are used solely to identify the equipment and protocols iLEAN Connect connectors are compatible with.