iLEAN Connect · PLC connectors
Connect a tray sealer to AI — plug & play iLEAN Connect connector
On a tray sealer every cycle is either units shipped or units pulled. Connected, both get counted — and every tooling change gets a price.
A tray sealer is a cycle machine, which makes its data clean: cycles completed, trays per cycle and therefore units sealed per format and per batch. Beside that sit the signals that explain the shift — real cycle time against nominal, stops for tooling or film reel changes, waiting for product, and the events the machine itself raises when a cycle does not complete as it should.
On the panel the manager sees the shift split by format, with each tooling changeover genuinely measured. That figure is usually the surprise: on a line with many SKUs, changeovers consume a share of the day nobody had quantified. Alongside it, the real sealing rate per format and the frequency of micro-stops. The iLEAN agent flags cycle time stretching or incidents clustering on one particular format.
Tray sealers usually carry an embedded controller under the builder's housing, and you do not need to know which one: it is identified at the technical visit. On simpler units the panel is read and cycles counted with our own sensors. The path is written into the scope document.
The decision: plan the day's SKU sequence to minimise tooling changes, attack the format accumulating the most incidents, and see whether the sealer is really the bottleneck or just where somebody else's bottleneck becomes visible.
Your machine connects, whether or not you know what is inside it
If it has no PLC
Plenty of machines in production predate the network. They connect all the same: an industrial camera watches the panel and reads what it shows, or the paper logs filled in by hand are captured by photo. Without touching the machine and without affecting its warranty.
If the PLC is embedded and you don't know which one
That is the norm. The builder fitted it under the housing and the documentation never says. You do not need to know: we identify it during the technical visit and the scope follows from there. You do not have to research anything before writing to us.
If you do know the PLC
Even better: there is probably already a standard connector for that family. Check the PLC connector catalog.
How it works
- Define the scope. Tell us what you want to see from your machine in the form. The form itself is the scope document: no separate paperwork.
- Quoted in 24 hours. You receive the quote within 24 business hours. If your connector is standard, direct activation — from €79/month per machine.
- Running in under 7 days. From your approval of the quote, the integration is running in under 7 days. You pay once you confirm it does what you expected.
What you get with the connector
- A panel of your machine, always visible, with history and charts.
- The iLEAN central memory continuously fed with signals, states, counters, alarms and variables.
- An AI agent analyzing the data and flagging deviations.
- A daily email summary of what happened on your line.
- Optional push to your ERP.
The connector is the doorway to the rest of the system: when you need it, the same machine scales to iLEAN Edge (inline machine vision, millisecond loop) and iLEAN Agents (full-cycle agents on the central memory).
How the guarantee works
Every iLEAN Connect integration is contracted the same way, and the terms are right here in the open:
- You define the scope of the connection you want: which signals, states, counters, alarms and variables to read from your PLC or machine.
- iLEAN quotes it within 24 business hours.
- If you approve, iLEAN builds it in under 7 days. The clock starts at your approval of the quote.
- iLEAN presents the integration to you, running.
- You confirm it does what you expected — the criterion is written into the scope document itself.
- Only then do you pay. Integrations 100% at reversed risk.
Need the AI to also act on the line? Define it in the scope and we quote it in 24 hours all the same; the build time is agreed in the scope document.
This guarantee covers the standard data connector: reading signals, states, counters, alarms and variables, delivery to the iLEAN central memory, a panel with history and charts, an agent analyzing, a daily email summary and optional push to your ERP.
The price, in the open
Standard catalog connector
From €79/month per machine. Your machine always online in the central memory, a panel with history, an agent analyzing and a daily email summary.
Custom integration
Its price is the 24-hour quote. The build is quoted once; afterwards, your machine joins the same fee — from €79/month.
Several machines with the same PLC? Volume pricing is negotiated case by case — ten identical connectors do not cost ten fees.
Why iLEAN can promise this
25+ years integrating AI with plant automation. Every driver, every protocol, every quirk of every PLC family is solved because it was already solved in a real plant: at Tier-1 manufacturers across automotive, aerospace, food, pharma and chemicals, and at the industrial SMEs that supply them.
AI is one more sensor — one that sees. Your PLC receives iLEAN's signal the way it receives any sensor's.
Frequently asked questions
Do we have to touch the PLC program?
No. The connector reads non-intrusively: AI is one more sensor, and your control logic stays exactly as it is. Writing to the PLC only exists if you expressly request it in the scope document.
What if the integration doesn't do what we expected?
You don't pay for it. The scope document defines in writing what «does what you expected» means, and payment comes after you confirm it, watching the integration run.
What network requirements does it need?
An outbound path from the plant network to the iLEAN central memory, with no inbound access opened. The concrete architecture — zones, rings, who talks to whom — is detailed in the scope document.
What if my machine has no PLC?
It connects too: through a camera on the panel or a photo of the paper log, the same iLEAN Connect paths used by plants with pre-network machinery.
Can output be counted per tray format?
Yes: cycles become units from the loaded format, read off the machine where it exposes it or tied in through the production order. Each format keeps its own rate, its own stoppages and its own incidents.
Is tooling changeover time recorded?
Yes, with its start and end, classified as planned downtime separately from breakdowns. It is one of the figures that turns into money fastest once the SKU sequence is planned with it in view.
More cases in connect any machine to ai
- Connect an ingredient mixer to AI — plug & play iLEAN Connect connectorRecipe as executed against recipe as written, batch by batch, with real times and weights. Quoted in…
- Connect an industrial labeling machine to AI — plug & play iLEAN Connect connectorPacks labeled against packs passed, reel-out stoppages and the time each changeover costs. Quoted in…
- Connect an industrial planetary mixer to AI — plug & play iLEAN Connect connectorReal time and speed per batch against the recipe, plus the dough's motor load signature. Quoted in 24h,…
- Connect an ultrasonic food cutter to AI — plug & play iLEAN Connect connectorPortions per piece, trim waste and blade cleaning stops, by format. Quoted in 24h, running in under 7…
- Connect a food X-ray inspection system to AI — plug & play iLEAN Connect connectorEvery reject with its time, batch and record, plus the rate per shift and product. Quoted in 24h, paid…
- Connect refrigeration and freezing equipment to AICold rooms, blast chillers, IQF tunnels and ice machines, connected. Quoted in 24h, running in under 7…
This form is the scope document: from what you write here, iLEAN prepares your quote. You have it within 24 business hours.
SIMATIC, S7 and LOGO! are trademarks of Siemens AG. Allen-Bradley, ControlLogix, CompactLogix, MicroLogix, Micro800 and SLC are trademarks of Rockwell Automation, Inc. Modicon is a trademark of Schneider Electric. MELSEC is a trademark of Mitsubishi Electric Corporation. SYSMAC is a trademark of OMRON Corporation. TwinCAT and EtherCAT are trademarks of Beckhoff Automation GmbH & Co. KG. X20 is a trademark of B&R Industrial Automation. AC500 is a trademark of ABB. PLCnext is a trademark of Phoenix Contact GmbH & Co. KG. WAGO and PFC are trademarks of WAGO GmbH & Co. KG. PACSystems and VersaMax are trademarks of Emerson Electric Co. PROFINET and PROFIBUS are trademarks of PROFIBUS Nutzerorganisation e.V. EtherNet/IP and CIP are trademarks of ODVA, Inc. OPC UA is a trademark of the OPC Foundation. Modbus is a trademark of Schneider Electric, licensed to the Modbus Organization. All other marks belong to their respective owners. iLEAN is not affiliated with, sponsored by, or endorsed by any of these manufacturers; their marks are used solely to identify the equipment and protocols iLEAN Connect connectors are compatible with.