iLEAN Connect · PLC connectors

Connect a vegetable cutter to AI — plug & play iLEAN Connect connector

On a cutter the money is not lost while cutting: it is lost in format changeovers and in the fines a tired blade produces. Both are measurable.

Three families of signal come off a connected cutter. Production: kilos or pieces per cut format, actual feed speed, cycles per hour. Changeover: every stop for a disc swap or a thickness adjustment, with the exact time it began and the time it resumed. Condition: cutting motor draw, safety stops from hopper opening, and micro-stops caused by uneven feeding.

What shows on the panel is a shift mapped by format: how much julienne was produced, how much dice, and how long it took to move from one to the other. In most plants that changeover time has never been measured, and it is the first figure that surprises people. Beside it sits the motor draw trend across the life of a blade set — the indirect way to watch cut quality degrade before the fines show up in the bag.

Connection is straightforward on recent cutters with their own drive and controller, and perfectly workable on older ones: the cabinet is read, cycles are counted with our own sensors, or the format log the operator fills in today is captured by photo. The technical visit says which suits your machine best.

The decision this drives is planning: group production by format so you pay for fewer changeovers, and schedule blade set replacement by what the machine says instead of by the calendar.

Your machine connects, whether or not you know what is inside it

If it has no PLC

Plenty of machines in production predate the network. They connect all the same: an industrial camera watches the panel and reads what it shows, or the paper logs filled in by hand are captured by photo. Without touching the machine and without affecting its warranty.

If the PLC is embedded and you don't know which one

That is the norm. The builder fitted it under the housing and the documentation never says. You do not need to know: we identify it during the technical visit and the scope follows from there. You do not have to research anything before writing to us.

If you do know the PLC

Even better: there is probably already a standard connector for that family. Check the PLC connector catalog.

How it works

  1. Define the scope. Tell us what you want to see from your machine in the form. The form itself is the scope document: no separate paperwork.
  2. Quoted in 24 hours. You receive the quote within 24 business hours. If your connector is standard, direct activation — from €79/month per machine.
  3. Running in under 7 days. From your approval of the quote, the integration is running in under 7 days. You pay once you confirm it does what you expected.

What you get with the connector

  • A panel of your machine, always visible, with history and charts.
  • The iLEAN central memory continuously fed with signals, states, counters, alarms and variables.
  • An AI agent analyzing the data and flagging deviations.
  • A daily email summary of what happened on your line.
  • Optional push to your ERP.

The connector is the doorway to the rest of the system: when you need it, the same machine scales to iLEAN Edge (inline machine vision, millisecond loop) and iLEAN Agents (full-cycle agents on the central memory).

How the guarantee works

Every iLEAN Connect integration is contracted the same way, and the terms are right here in the open:

  1. You define the scope of the connection you want: which signals, states, counters, alarms and variables to read from your PLC or machine.
  2. iLEAN quotes it within 24 business hours.
  3. If you approve, iLEAN builds it in under 7 days. The clock starts at your approval of the quote.
  4. iLEAN presents the integration to you, running.
  5. You confirm it does what you expected — the criterion is written into the scope document itself.
  6. Only then do you pay. Integrations 100% at reversed risk.

Need the AI to also act on the line? Define it in the scope and we quote it in 24 hours all the same; the build time is agreed in the scope document.

This guarantee covers the standard data connector: reading signals, states, counters, alarms and variables, delivery to the iLEAN central memory, a panel with history and charts, an agent analyzing, a daily email summary and optional push to your ERP.

The price, in the open

Standard catalog connector

From €79/month per machine. Your machine always online in the central memory, a panel with history, an agent analyzing and a daily email summary.

Custom integration

Its price is the 24-hour quote. The build is quoted once; afterwards, your machine joins the same fee — from €79/month.

Several machines with the same PLC? Volume pricing is negotiated case by case — ten identical connectors do not cost ten fees.

Why iLEAN can promise this

25+ years integrating AI with plant automation. Every driver, every protocol, every quirk of every PLC family is solved because it was already solved in a real plant: at Tier-1 manufacturers across automotive, aerospace, food, pharma and chemicals, and at the industrial SMEs that supply them.

AI is one more sensor — one that sees. Your PLC receives iLEAN's signal the way it receives any sensor's.

Frequently asked questions

Do we have to touch the PLC program?

No. The connector reads non-intrusively: AI is one more sensor, and your control logic stays exactly as it is. Writing to the PLC only exists if you expressly request it in the scope document.

What if the integration doesn't do what we expected?

You don't pay for it. The scope document defines in writing what «does what you expected» means, and payment comes after you confirm it, watching the integration run.

What network requirements does it need?

An outbound path from the plant network to the iLEAN central memory, with no inbound access opened. The concrete architecture — zones, rings, who talks to whom — is detailed in the scope document.

What if my machine has no PLC?

It connects too: through a camera on the panel or a photo of the paper log, the same iLEAN Connect paths used by plants with pre-network machinery.

Can the system know which cut format is running?

If the machine exposes it — recipe or disc selection on its panel — it is read directly. If not, it is tied to the production log or to the operator's selection on the line terminal. The scope document decides which of the two paths your plant uses.

Does a format changeover count as downtime?

It is recorded as a stop, but classified separately: a planned format changeover and a breakdown do not mean the same thing and should not pollute the same indicator. The cause classification is agreed with you in the scope.

Define your scope — quoted in 24 hours

This form is the scope document: from what you write here, iLEAN prepares your quote. You have it within 24 business hours.