iLEAN Connect · PLC connectors
Connect a snack extruder to AI — plug & play iLEAN Connect connector
Screw torque, zone temperatures and die pressure, placed next to the real density of the product coming out.
An extruder talks constantly: motor torque, temperatures per zone, pressure before the die, flour and water dosing, screw speed and kilos per hour. What almost never happens is storing those signals next to the result — density, expansion, moisture — so you can answer why Tuesday's start-up took forty minutes to make good product.
Connected, the panel shows start-up as a curve: how long each zone took to stabilise, when pressure came into range, and how much product went out meanwhile. It also shows the whole shift, with the torque drift that announces wear or a different flour. The AI agent warns when the process departs from that reference's known pattern.
The decision: shorten start-ups by repeating the one that went best, adjust before making out-of-spec product, and schedule die or screw changes on real hours. The seasoning applicator is the next point where the same batch is worth money.
Your machine connects, whether or not you know what is inside it
If it has no PLC
Plenty of machines in production predate the network. They connect all the same: an industrial camera watches the panel and reads what it shows, or the paper logs filled in by hand are captured by photo. Without touching the machine and without affecting its warranty.
If the PLC is embedded and you don't know which one
That is the norm. The builder fitted it under the housing and the documentation never says. You do not need to know: we identify it during the technical visit and the scope follows from there. You do not have to research anything before writing to us.
If you do know the PLC
Even better: there is probably already a standard connector for that family. Check the PLC connector catalog.
How it works
- Define the scope. Tell us what you want to see from your machine in the form. The form itself is the scope document: no separate paperwork.
- Quoted in 24 hours. You receive the quote within 24 business hours. If your connector is standard, direct activation — from €79/month per machine.
- Running in under 7 days. From your approval of the quote, the integration is running in under 7 days. You pay once you confirm it does what you expected.
What you get with the connector
- A panel of your machine, always visible, with history and charts.
- The iLEAN central memory continuously fed with signals, states, counters, alarms and variables.
- An AI agent analyzing the data and flagging deviations.
- A daily email summary of what happened on your line.
- Optional push to your ERP.
The connector is the doorway to the rest of the system: when you need it, the same machine scales to iLEAN Edge (inline machine vision, millisecond loop) and iLEAN Agents (full-cycle agents on the central memory).
How the guarantee works
Every iLEAN Connect integration is contracted the same way, and the terms are right here in the open:
- You define the scope of the connection you want: which signals, states, counters, alarms and variables to read from your PLC or machine.
- iLEAN quotes it within 24 business hours.
- If you approve, iLEAN builds it in under 7 days. The clock starts at your approval of the quote.
- iLEAN presents the integration to you, running.
- You confirm it does what you expected — the criterion is written into the scope document itself.
- Only then do you pay. Integrations 100% at reversed risk.
Need the AI to also act on the line? Define it in the scope and we quote it in 24 hours all the same; the build time is agreed in the scope document.
This guarantee covers the standard data connector: reading signals, states, counters, alarms and variables, delivery to the iLEAN central memory, a panel with history and charts, an agent analyzing, a daily email summary and optional push to your ERP.
The price, in the open
Standard catalog connector
From €79/month per machine. Your machine always online in the central memory, a panel with history, an agent analyzing and a daily email summary.
Custom integration
Its price is the 24-hour quote. The build is quoted once; afterwards, your machine joins the same fee — from €79/month.
Several machines with the same PLC? Volume pricing is negotiated case by case — ten identical connectors do not cost ten fees.
Why iLEAN can promise this
25+ years integrating AI with plant automation. Every driver, every protocol, every quirk of every PLC family is solved because it was already solved in a real plant: at Tier-1 manufacturers across automotive, aerospace, food, pharma and chemicals, and at the industrial SMEs that supply them.
AI is one more sensor — one that sees. Your PLC receives iLEAN's signal the way it receives any sensor's.
Frequently asked questions
Do we have to touch the PLC program?
No. The connector reads non-intrusively: AI is one more sensor, and your control logic stays exactly as it is. Writing to the PLC only exists if you expressly request it in the scope document.
What if the integration doesn't do what we expected?
You don't pay for it. The scope document defines in writing what «does what you expected» means, and payment comes after you confirm it, watching the integration run.
What network requirements does it need?
An outbound path from the plant network to the iLEAN central memory, with no inbound access opened. The concrete architecture — zones, rings, who talks to whom — is detailed in the scope document.
What if my machine has no PLC?
It connects too: through a camera on the panel or a photo of the paper log, the same iLEAN Connect paths used by plants with pre-network machinery.
Can torque be related to the quality of the product coming out?
Yes, and it is usually the finding: with density or moisture measured in line or in the lab feeding the same panel, the link between process and result stops being intuition. Which measurements are included is defined in the scope.
Does the connector count product lost at start-up?
It counts the time to in-spec product and the kilos produced during that stretch, which is the practical way to value it. That lets start-ups be compared and the best one adopted as the reference.
More cases in connect any machine to ai
- Connect a batch fryer to AI — plug & play iLEAN Connect connectorOil curve per batch, real frying time and accumulated oil hours. Quoted in 24h, paid once you see it…
- Connect an industrial roaster to AI — plug & play iLEAN Connect connectorRoast profile per batch, temperature, time and cooling in one panel. Quoted in 24h, paid once you see it…
- Connect a seasoning applicator to AI — plug & play iLEAN Connect connectorThe real seasoning dose per kilo of product, batch by batch. Quoted in 24h, running in under 7 days,…
- Connect bakery and pastry machinery to AIDividers, ovens, coolers and baggers feeding their data to AI. Quoted in 24h, running in under 7 days…
- Connect a baguette moulder to AI — plug & play iLEAN Connect connectorLoaves per hour, jams with their timestamp and format-change minutes. Quoted in 24h, running in under 7…
- Connect a batter depositor to AI — plug & play iLEAN Connect connectorDeposits per minute, weight per mould and nozzle-to-nozzle drift. Quoted in 24h, running in under 7 days…
This form is the scope document: from what you write here, iLEAN prepares your quote. You have it within 24 business hours.
SIMATIC, S7 and LOGO! are trademarks of Siemens AG. Allen-Bradley, ControlLogix, CompactLogix, MicroLogix, Micro800 and SLC are trademarks of Rockwell Automation, Inc. Modicon is a trademark of Schneider Electric. MELSEC is a trademark of Mitsubishi Electric Corporation. SYSMAC is a trademark of OMRON Corporation. TwinCAT and EtherCAT are trademarks of Beckhoff Automation GmbH & Co. KG. X20 is a trademark of B&R Industrial Automation. AC500 is a trademark of ABB. PLCnext is a trademark of Phoenix Contact GmbH & Co. KG. WAGO and PFC are trademarks of WAGO GmbH & Co. KG. PACSystems and VersaMax are trademarks of Emerson Electric Co. PROFINET and PROFIBUS are trademarks of PROFIBUS Nutzerorganisation e.V. EtherNet/IP and CIP are trademarks of ODVA, Inc. OPC UA is a trademark of the OPC Foundation. Modbus is a trademark of Schneider Electric, licensed to the Modbus Organization. All other marks belong to their respective owners. iLEAN is not affiliated with, sponsored by, or endorsed by any of these manufacturers; their marks are used solely to identify the equipment and protocols iLEAN Connect connectors are compatible with.