iLEAN Connect · PLC connectors
Connect a CIP system to AI — plug & play iLEAN Connect connector
That the caustic phase reached its temperature and its time, on that circuit and at that hour, and that it is on record.
In data terms a CIP is a sequence of phases that either were met or were not. That is exactly what to read: which circuit was washed, when each phase started and ended, the temperature reached in the caustic phase and how long it was held, concentration or conductivity, return flow, and the final rinse. Plus the exceptions: aborted washes, shortened phases, circuits that were skipped.
Connected, every wash lands on the panel as a closed record, with its circuit, its time and its phases in green or red. When the IFS or BRC audit arrives, months of wash history are available with nothing rebuilt: it is the same data currently written by hand on a sheet somebody has to fill in and somebody else has to file. A CIP skid usually has its own controller and publishes a fair amount, but where it does not, the required probes and flow measurement are fitted during the technical visit.
The data decides on food safety and chemical cost at the same time. On one side, a wash that missed parameter is flagged before production runs on that circuit, not after a positive swab. On the other, real caustic, acid and water consumption per wash and per circuit shows which programs are oversized and lets you trim them with the record in hand.
Your machine connects, whether or not you know what is inside it
If it has no PLC
Plenty of machines in production predate the network. They connect all the same: an industrial camera watches the panel and reads what it shows, or the paper logs filled in by hand are captured by photo. Without touching the machine and without affecting its warranty.
If the PLC is embedded and you don't know which one
That is the norm. The builder fitted it under the housing and the documentation never says. You do not need to know: we identify it during the technical visit and the scope follows from there. You do not have to research anything before writing to us.
If you do know the PLC
Even better: there is probably already a standard connector for that family. Check the PLC connector catalog.
How it works
- Define the scope. Tell us what you want to see from your machine in the form. The form itself is the scope document: no separate paperwork.
- Quoted in 24 hours. You receive the quote within 24 business hours. If your connector is standard, direct activation — from €79/month per machine.
- Running in under 7 days. From your approval of the quote, the integration is running in under 7 days. You pay once you confirm it does what you expected.
What you get with the connector
- A panel of your machine, always visible, with history and charts.
- The iLEAN central memory continuously fed with signals, states, counters, alarms and variables.
- An AI agent analyzing the data and flagging deviations.
- A daily email summary of what happened on your line.
- Optional push to your ERP.
The connector is the doorway to the rest of the system: when you need it, the same machine scales to iLEAN Edge (inline machine vision, millisecond loop) and iLEAN Agents (full-cycle agents on the central memory).
How the guarantee works
Every iLEAN Connect integration is contracted the same way, and the terms are right here in the open:
- You define the scope of the connection you want: which signals, states, counters, alarms and variables to read from your PLC or machine.
- iLEAN quotes it within 24 business hours.
- If you approve, iLEAN builds it in under 7 days. The clock starts at your approval of the quote.
- iLEAN presents the integration to you, running.
- You confirm it does what you expected — the criterion is written into the scope document itself.
- Only then do you pay. Integrations 100% at reversed risk.
Need the AI to also act on the line? Define it in the scope and we quote it in 24 hours all the same; the build time is agreed in the scope document.
This guarantee covers the standard data connector: reading signals, states, counters, alarms and variables, delivery to the iLEAN central memory, a panel with history and charts, an agent analyzing, a daily email summary and optional push to your ERP.
The price, in the open
Standard catalog connector
From €79/month per machine. Your machine always online in the central memory, a panel with history, an agent analyzing and a daily email summary.
Custom integration
Its price is the 24-hour quote. The build is quoted once; afterwards, your machine joins the same fee — from €79/month.
Several machines with the same PLC? Volume pricing is negotiated case by case — ten identical connectors do not cost ten fees.
Why iLEAN can promise this
25+ years integrating AI with plant automation. Every driver, every protocol, every quirk of every PLC family is solved because it was already solved in a real plant: at Tier-1 manufacturers across automotive, aerospace, food, pharma and chemicals, and at the industrial SMEs that supply them.
AI is one more sensor — one that sees. Your PLC receives iLEAN's signal the way it receives any sensor's.
Frequently asked questions
Do we have to touch the PLC program?
No. The connector reads non-intrusively: AI is one more sensor, and your control logic stays exactly as it is. Writing to the PLC only exists if you expressly request it in the scope document.
What if the integration doesn't do what we expected?
You don't pay for it. The scope document defines in writing what «does what you expected» means, and payment comes after you confirm it, watching the integration run.
What network requirements does it need?
An outbound path from the plant network to the iLEAN central memory, with no inbound access opened. The concrete architecture — zones, rings, who talks to whom — is detailed in the scope document.
What if my machine has no PLC?
It connects too: through a camera on the panel or a photo of the paper log, the same iLEAN Connect paths used by plants with pre-network machinery.
Does the connector's log count as evidence in an IFS or BRC audit?
It is an automatic, timestamped record of every phase of every wash, with circuit, temperature and duration, that cannot be filled in by hand. It is exactly the kind of evidence that replaces the handwritten sheet, and it exports on request.
Does it flag washes that missed their parameters?
Yes. Each phase is compared against what it had to meet, and deviations are marked with their time and their circuit, so you act before producing on that equipment.
More cases in connect any machine to ai
- Connect a liquid egg filler to AISee the extra kilos per bag-in-box and sealing rejects by format. Quoted in 24h, running in under 7…
- Connect a liquid egg pasteurizer to AIContinuous record of temperature, holding time and diversions per batch, audit-ready. Quoted in 24h and…
- Connect your general plant equipment to AICompressors, boilers, CIP, scales, RO and metal detectors, connected. Quoted in 24h, running in under 7…
- Connect an industrial food scale to AI — plug & play iLEAN Connect connectorEvery weighing with its time, batch and operator, and drift from target. Quoted in 24h, running in under…
- Connect an industrial metal detector to AI — plug & play iLEAN Connect connectorEvery reject with its time and batch, every test with its result. Quoted in 24h, running in under 7 days…
- Connect a food-grade oil-free air compressor to AI — plug & play iLEAN Connect connectorLoaded hours, starts, line pressure and consumption per line. Quoted in 24h, running in under 7 days and…
This form is the scope document: from what you write here, iLEAN prepares your quote. You have it within 24 business hours.
SIMATIC, S7 and LOGO! are trademarks of Siemens AG. Allen-Bradley, ControlLogix, CompactLogix, MicroLogix, Micro800 and SLC are trademarks of Rockwell Automation, Inc. Modicon is a trademark of Schneider Electric. MELSEC is a trademark of Mitsubishi Electric Corporation. SYSMAC is a trademark of OMRON Corporation. TwinCAT and EtherCAT are trademarks of Beckhoff Automation GmbH & Co. KG. X20 is a trademark of B&R Industrial Automation. AC500 is a trademark of ABB. PLCnext is a trademark of Phoenix Contact GmbH & Co. KG. WAGO and PFC are trademarks of WAGO GmbH & Co. KG. PACSystems and VersaMax are trademarks of Emerson Electric Co. PROFINET and PROFIBUS are trademarks of PROFIBUS Nutzerorganisation e.V. EtherNet/IP and CIP are trademarks of ODVA, Inc. OPC UA is a trademark of the OPC Foundation. Modbus is a trademark of Schneider Electric, licensed to the Modbus Organization. All other marks belong to their respective owners. iLEAN is not affiliated with, sponsored by, or endorsed by any of these manufacturers; their marks are used solely to identify the equipment and protocols iLEAN Connect connectors are compatible with.