iLEAN Connect · PLC connectors

Connect a divider rounder to AI — plug & play iLEAN Connect connector

The first machine on the line sets the weight of everything downstream: connect it and stop estimating it.

From a divider rounder the signals worth reading are the ones that decide the cost of the day: cycles executed, pieces per cycle, active recipe or format, time between cycles, and every stop with its exact timestamp. If the machine also exposes pressing pressure or head adjustment position, those go into the scope too. And if weight is verified on a scale or checkweigher downstream on your line, that weight is matched to the cycle that produced it: that is where drift shows up.

Once connected, the bakery manager opens the panel and sees the shift in progress: actual pieces against plan, how many minutes went into format changes, at what moment the machine stopped and how long each stop lasted. History lets you compare the same product on Monday and Thursday, or the morning shift against the night shift, without arguing from memory. The reading path depends on what is inside — its own panel, an embedded controller or, if there is nothing to read, an industrial camera watching the display — and the technical visit decides it.

The decision the data unlocks is a direct one: how much dough is being given away. A small, sustained drift in division weight is invisible on one piece, but you see all of it at month end in flour consumed against units sold. With the history in front of you it is clear whether the drift belongs to one format, one shift or the day after cleaning — and you correct it where it lives instead of nudging the adjustment by eye.

Your machine connects, whether or not you know what is inside it

If it has no PLC

Plenty of machines in production predate the network. They connect all the same: an industrial camera watches the panel and reads what it shows, or the paper logs filled in by hand are captured by photo. Without touching the machine and without affecting its warranty.

If the PLC is embedded and you don't know which one

That is the norm. The builder fitted it under the housing and the documentation never says. You do not need to know: we identify it during the technical visit and the scope follows from there. You do not have to research anything before writing to us.

If you do know the PLC

Even better: there is probably already a standard connector for that family. Check the PLC connector catalog.

How it works

  1. Define the scope. Tell us what you want to see from your machine in the form. The form itself is the scope document: no separate paperwork.
  2. Quoted in 24 hours. You receive the quote within 24 business hours. If your connector is standard, direct activation — from €79/month per machine.
  3. Running in under 7 days. From your approval of the quote, the integration is running in under 7 days. You pay once you confirm it does what you expected.

What you get with the connector

  • A panel of your machine, always visible, with history and charts.
  • The iLEAN central memory continuously fed with signals, states, counters, alarms and variables.
  • An AI agent analyzing the data and flagging deviations.
  • A daily email summary of what happened on your line.
  • Optional push to your ERP.

The connector is the doorway to the rest of the system: when you need it, the same machine scales to iLEAN Edge (inline machine vision, millisecond loop) and iLEAN Agents (full-cycle agents on the central memory).

How the guarantee works

Every iLEAN Connect integration is contracted the same way, and the terms are right here in the open:

  1. You define the scope of the connection you want: which signals, states, counters, alarms and variables to read from your PLC or machine.
  2. iLEAN quotes it within 24 business hours.
  3. If you approve, iLEAN builds it in under 7 days. The clock starts at your approval of the quote.
  4. iLEAN presents the integration to you, running.
  5. You confirm it does what you expected — the criterion is written into the scope document itself.
  6. Only then do you pay. Integrations 100% at reversed risk.

Need the AI to also act on the line? Define it in the scope and we quote it in 24 hours all the same; the build time is agreed in the scope document.

This guarantee covers the standard data connector: reading signals, states, counters, alarms and variables, delivery to the iLEAN central memory, a panel with history and charts, an agent analyzing, a daily email summary and optional push to your ERP.

The price, in the open

Standard catalog connector

From €79/month per machine. Your machine always online in the central memory, a panel with history, an agent analyzing and a daily email summary.

Custom integration

Its price is the 24-hour quote. The build is quoted once; afterwards, your machine joins the same fee — from €79/month.

Several machines with the same PLC? Volume pricing is negotiated case by case — ten identical connectors do not cost ten fees.

Why iLEAN can promise this

25+ years integrating AI with plant automation. Every driver, every protocol, every quirk of every PLC family is solved because it was already solved in a real plant: at Tier-1 manufacturers across automotive, aerospace, food, pharma and chemicals, and at the industrial SMEs that supply them.

AI is one more sensor — one that sees. Your PLC receives iLEAN's signal the way it receives any sensor's.

Frequently asked questions

Do we have to touch the PLC program?

No. The connector reads non-intrusively: AI is one more sensor, and your control logic stays exactly as it is. Writing to the PLC only exists if you expressly request it in the scope document.

What if the integration doesn't do what we expected?

You don't pay for it. The scope document defines in writing what «does what you expected» means, and payment comes after you confirm it, watching the integration run.

What network requirements does it need?

An outbound path from the plant network to the iLEAN central memory, with no inbound access opened. The concrete architecture — zones, rings, who talks to whom — is detailed in the scope document.

What if my machine has no PLC?

It connects too: through a camera on the panel or a photo of the paper log, the same iLEAN Connect paths used by plants with pre-network machinery.

Can we know the real weight of each division if the machine doesn't measure it?

It comes from matching the divider cycle to whatever weighing already exists downstream — control scale, checkweigher or tray weighing. Say in the scope document what weighing you have inline and the quote arrives with that correlation included.

Do we have to stop production to connect it?

No. Reading is non-intrusive and is prepared with the machine running; installation is coordinated with your cleaning or shift-change window so it does not cost you a single bake.

Define your scope — quoted in 24 hours

This form is the scope document: from what you write here, iLEAN prepares your quote. You have it within 24 business hours.